HOME ¢¹ Á¦Ç°¼Ò°³ ¢¹ In Building Repeater |
|
|
|
|
|
Compact Size
ALC Function Shut-Down Function
Superior Performance
Low Power Consumption |
|
|
Electrical Specification |
| Parameters |
Standards |
Remark |
| Frequency |
All Wireless System band |
CELLULAR, GSM, DCS, PCS, WCDMA |
| Bandwidth |
Customize Acceptable |
|
| GAIN |
60 dB |
|
| GAIN FLATNESS |
¡¾1.5dB |
|
| V.S.W.R. |
1.5 : 1 |
|
| Input Power Range |
-104 ~ -40 dBm |
|
| Max. Output Power |
0dBm( 1mW ) |
@Total Output Power |
| IMD |
CDMA:£¼ -15 dBm GSM:£¼ -36 dBm DCS:£¼ -30 dBm |
@Max Output Power |
| Spurious |
CDMA £¼ -45dBc/30KHz @ fc ¡¾ 750KHz £¼ -60dBc/30KHz @ fc ¡¾ 1.98MHz GSM Meet ETSI Standard |
@Max Output Power |
| Noise Figure |
CDMA :£¼5dB GSM : £¼6dB |
|
| Impedance |
50¥Ø |
|
| Group Delay |
2§Á |
|
| Power Supply |
AC : 110~220V, 50~60Hz |
Operating Voltage @DC Adaptor(2.0A Max) |
|
Control Options Specification |
| Parameters |
Standards |
Remark |
| AGC,ALC RANGE |
20dB |
|
| Gain Control Type |
Not Used |
|
| Step Attenuation |
DC Power Alarm Shut Down Alarm |
|
| NMS |
Not Used |
|
|
Physical Specification |
| Parameters |
Standards |
Remark |
| In/Out Connector |
N Type Female |
|
| Weight |
¡Â 2 |
§¸ |
| Step Attenuation |
DC Power Alarm Shut Down Alarm |
|
| Dimension (W¡¿H¡¿D) |
140 ¡¿ 163 ¡¿ 45 |
mm |
|
Environmental Specification |
| Parameters |
Standards |
Remark |
| Operating Temperature |
-10 ~ +55 |
¡É |
| Relative Humidity |
10 ~ 90 |
£¥ |
| Enclosure Protection |
Full Protection Against Dust Insertion |
|
|
The enclosure shall have no damage or degradation and the electrical specifications shall be maintained under above conditions. Customer design and specifications are available. |
|
| |
| |
|